Brand Name: | HXCOWO |
Model Number: | HX-DL1 |
MOQ: | 1000 meters |
ราคา: | Negotiable |
Packaging Details: | Wooden shaft+Export cardboard box |
2-288 Core Dielectric ADSS Fiber Optic Cable G652D/G657A1/G657A2 for Outdoor Aerial
PRODUCT PARAMETERS
|
|
|
|
|
|
|||||
Single Sheath
|
|
|
|
|
|
|||||
Reference outer diameter
(mm)
|
Reference weight
(Kg/Km)
|
|
Daily average working tension
(KN)
|
Maximum allowable working tension
(KN)
|
Breaking strength
(KN)
|
|||||
|
PE outer sheath
|
AT outer sheath
|
|
|
|
|||||
9.0
|
75
|
85
|
1.2
|
3
|
7
|
|||||
9.8
|
80
|
90
|
1.5
|
5
|
10
|
|||||
10
|
90
|
100
|
2
|
6
|
15
|
|||||
10
|
90
|
100
|
2.2
|
8
|
18
|
|||||
Tensile element cross-sectional area (㎜²)
|
Elastic Modulus
(KN/㎜²)
|
|
Operating, storage and transport temperature range
(℃)
|
Thermal expansion coefficient
(10-6/K)
|
suitable span
(M)
|
|||||
3
|
4.5
|
|
-40~+60
|
1.2
|
50
|
|||||
3.5
|
7
|
|
-40~+60
|
1.3
|
100
|
|||||
4.5
|
8.3
|
|
-40~+60
|
1.3
|
150
|
|||||
7.5
|
9.5
|
|
-40~+60
|
1.3
|
200
|
Double Sheath
|
|
|
|
|
|
|||||
Reference outer diameter
(mm)
|
Reference weight
(Kg/Km)
|
|
Daily average working tension
(KN)
|
Maximum allowable working tension
(KN)
|
Breaking strength (KN)
|
|||||
|
PE outer sheath
|
AT outer sheath
|
|
|
|
|||||
11.5
|
125
|
136
|
1.5
|
4
|
10
|
|||||
12
|
132
|
142
|
2.25
|
6
|
15
|
|||||
13.3
|
137
|
148
|
3
|
8
|
20
|
|||||
13.6
|
145
|
156
|
3.6
|
10
|
24
|
|||||
13.8
|
147
|
159
|
4.5
|
12
|
30
|
|||||
14.5
|
164
|
177
|
5.4
|
15
|
36
|
|||||
14.9
|
171
|
185
|
6.75
|
18
|
45
|
|||||
15.1
|
179
|
193
|
7.95
|
22
|
53
|
Tensile element cross-sectional area (㎜²)
|
Elastic Modulus
(KN/㎜²)
|
Operating, storage and transport temperature range (℃)
|
Thermal expansion coefficient
(10-6/K)
|
Suitable span (m) (corresponding to meteorological conditions)
|
|
|
|
|||
|
|
|
|
A
|
B
|
C
|
D
|
|||
4.6
|
7.6
|
-40~+60
|
1.8
|
160
|
100
|
140
|
100
|
|||
7.6
|
8.3
|
-40~+60
|
1.5
|
230
|
150
|
200
|
150
|
|||
10.35
|
9.45
|
-40~+60
|
1.3
|
300
|
200
|
290
|
200
|
|||
13.8
|
10.8
|
-40~+60
|
1.2
|
370
|
250
|
350
|
250
|
|||
14.3
|
11.8
|
-40~+60
|
1.0
|
420
|
280
|
400
|
280
|
|||
18.4
|
13.6
|
-40~+60
|
0.9
|
480
|
320
|
460
|
320
|
|||
22
|
16.4
|
-40~+60
|
0.6
|
570
|
380
|
550
|
380
|
|||
26.4
|
18
|
-40~+60
|
0.3
|
670
|
460
|
650
|
460
|
Meteorological region
|
Wind speed (m/s)
|
Icing (mm)
|
Extra negative (N/m)
|
A
|
25
|
0
|
0.7
|
B
|
35
|
0
|
0.7
|
C
|
10
|
5
|
2.5
|
D
|
10
|
10
|
4.4
|
Brand Name: | HXCOWO |
Model Number: | HX-DL1 |
MOQ: | 1000 meters |
ราคา: | Negotiable |
Packaging Details: | Wooden shaft+Export cardboard box |
2-288 Core Dielectric ADSS Fiber Optic Cable G652D/G657A1/G657A2 for Outdoor Aerial
PRODUCT PARAMETERS
|
|
|
|
|
|
|||||
Single Sheath
|
|
|
|
|
|
|||||
Reference outer diameter
(mm)
|
Reference weight
(Kg/Km)
|
|
Daily average working tension
(KN)
|
Maximum allowable working tension
(KN)
|
Breaking strength
(KN)
|
|||||
|
PE outer sheath
|
AT outer sheath
|
|
|
|
|||||
9.0
|
75
|
85
|
1.2
|
3
|
7
|
|||||
9.8
|
80
|
90
|
1.5
|
5
|
10
|
|||||
10
|
90
|
100
|
2
|
6
|
15
|
|||||
10
|
90
|
100
|
2.2
|
8
|
18
|
|||||
Tensile element cross-sectional area (㎜²)
|
Elastic Modulus
(KN/㎜²)
|
|
Operating, storage and transport temperature range
(℃)
|
Thermal expansion coefficient
(10-6/K)
|
suitable span
(M)
|
|||||
3
|
4.5
|
|
-40~+60
|
1.2
|
50
|
|||||
3.5
|
7
|
|
-40~+60
|
1.3
|
100
|
|||||
4.5
|
8.3
|
|
-40~+60
|
1.3
|
150
|
|||||
7.5
|
9.5
|
|
-40~+60
|
1.3
|
200
|
Double Sheath
|
|
|
|
|
|
|||||
Reference outer diameter
(mm)
|
Reference weight
(Kg/Km)
|
|
Daily average working tension
(KN)
|
Maximum allowable working tension
(KN)
|
Breaking strength (KN)
|
|||||
|
PE outer sheath
|
AT outer sheath
|
|
|
|
|||||
11.5
|
125
|
136
|
1.5
|
4
|
10
|
|||||
12
|
132
|
142
|
2.25
|
6
|
15
|
|||||
13.3
|
137
|
148
|
3
|
8
|
20
|
|||||
13.6
|
145
|
156
|
3.6
|
10
|
24
|
|||||
13.8
|
147
|
159
|
4.5
|
12
|
30
|
|||||
14.5
|
164
|
177
|
5.4
|
15
|
36
|
|||||
14.9
|
171
|
185
|
6.75
|
18
|
45
|
|||||
15.1
|
179
|
193
|
7.95
|
22
|
53
|
Tensile element cross-sectional area (㎜²)
|
Elastic Modulus
(KN/㎜²)
|
Operating, storage and transport temperature range (℃)
|
Thermal expansion coefficient
(10-6/K)
|
Suitable span (m) (corresponding to meteorological conditions)
|
|
|
|
|||
|
|
|
|
A
|
B
|
C
|
D
|
|||
4.6
|
7.6
|
-40~+60
|
1.8
|
160
|
100
|
140
|
100
|
|||
7.6
|
8.3
|
-40~+60
|
1.5
|
230
|
150
|
200
|
150
|
|||
10.35
|
9.45
|
-40~+60
|
1.3
|
300
|
200
|
290
|
200
|
|||
13.8
|
10.8
|
-40~+60
|
1.2
|
370
|
250
|
350
|
250
|
|||
14.3
|
11.8
|
-40~+60
|
1.0
|
420
|
280
|
400
|
280
|
|||
18.4
|
13.6
|
-40~+60
|
0.9
|
480
|
320
|
460
|
320
|
|||
22
|
16.4
|
-40~+60
|
0.6
|
570
|
380
|
550
|
380
|
|||
26.4
|
18
|
-40~+60
|
0.3
|
670
|
460
|
650
|
460
|
Meteorological region
|
Wind speed (m/s)
|
Icing (mm)
|
Extra negative (N/m)
|
A
|
25
|
0
|
0.7
|
B
|
35
|
0
|
0.7
|
C
|
10
|
5
|
2.5
|
D
|
10
|
10
|
4.4
|